Phoenix PSR-SCP- 24DC/URM4/5X1/2X2/B-expansion module 1442344, single-channel or dual-channel contact expansion, 5 normally open contacts, 1 normally closed contact, 1 feedback loop, and Basic equipment used together, in line with EN ISO 13849 safety isolation standard Cat. 4 class PL e requirements, width: 22.5mm, pluggable screw terminal
Product Type
safety relay
Product Series
PSRclassic
Application
Expansion Module
control
Single and Dual Channel
mechanical life
10x 106 Switch Times
Relay Model
Electromechanical relay with mechanical interlocking contacts according to IEC/EN 61810-3
insulation characteristics
Overvoltage Level
III
pollution level
2
Typical startup time (Us )
< 25 ms (with Us/via A1 control)
Typical release time
< 20 ms (with Us/via A1 control)
Recovery Time
< 1 s
Electrical characteristics
rated conditions
16.6W (US = 26.4 V, IL ² = 72 A², PTotal Maximum = 2.2W +14.4 W)
Rated operating mode
100% Eligible
Rated insulation voltage
250V
rated overvoltage/insulation
see section "Insulation Coordination" in the data sheet.
input data
digital quantity: A1
Input Description
safety related
Input Quantity
1
input voltage range, "1" signal
19.2V ... 26.4V
Allowable total conductor resistance
25 Ω
protection circuit
Suppressor Diode
power consumption
Typical 75 mA
Output Data
relay: enable current path (23/24 ... 63/64)
Output Description
2 normally open contacts each in series, safety-related, floating
outputs
5
Contact Type
5 normally open safety contact outputs
Contact Material
AgSnO2
Switching voltage
minimum 10V
Max. 250V AC/DC
on-off capacity
100 mW minimum
Impulse current
10 mA minimum
max. 20 A (≤ 100 ms)
limit continuous current
6 A (pay attention to capacity reduction)
the square of the total current value
72 A2 (pay attention to capacity reduction)
Switching frequency
max. 1Hz
mechanical life
10x 106 Switch Times
output fuse
10 A gL/gG
4 A gL/gG (for low-demand applications)
Relays: Signal Transmission Current Path (71/72)
Output Description
2 parallel normally closed contacts, non-safety related, floating
outputs
1
Contact Type
1 signal transmission current path
Contact Material
AgSnO2
Switching voltage
Minimum 5V AC/DC
Max. 250V AC/DC
on-off capacity
50 mW minimum
Impulse current
10 mA minimum
max. 6 A
limit continuous current
6 A
the square of the total current value
36 A2
Switching frequency
max. 1Hz
mechanical life
10x 106 Switch Times
output fuse
6 A (gL/gG)
Relays: Way Feedback Loops (11/12)
Output Description
diagnostic contacts, 2 series normally closed contacts, floating
outputs
1
Contact Type
1 feedback loop
Contact Material
AgSnO2
Switching voltage
minimum 10V
Max. 250V AC/DC
on-off capacity
100 mW minimum
Impulse current
10 mA minimum
max. 6 A
limit continuous current
6 A
the square of the total current value
36 A2
Switching frequency
max. 0.5Hz
mechanical life
10x 106 Switch Times
output fuse
10 A (gL/gG)