Phoenix CAPAROC E2 12-24DC/1-4A EX-Electronic equipment circuit breaker 1344361,2-channel electronic circuit breaker module, can protect 12V DC and 24V DC loads from overload and short circuit. The rated current can be adjusted between 1 A and 4 A by means of a step switch. Explosion proof zone 2 certified. The product is DIN-rail mounted via CAPAROC bus bars.

Product Type Equipment circuit breaker
Product Series CAPAROC
type plug-in module
Bits 1
Channels 2
slots 2
insulation characteristics
protection level III
pollution level 2

Overview
working voltage 10V DC ... 30V DC
Rated voltage 12V DC
24V DC
Nominal operating current IN 4 A DC (per channel)
Nominal operating current IN 1 / 2/3/4 A DC (adjusted by rotary code switch)
1 / 2/3/4 A DC (in RC mode, it can be set through the power module with communication interface)
Rated current (preset) 1 A
Rated overvoltage 0.5 kV
Breaking method E (Electronic)
feedback resistance Max 35V DC
impact suppression 50 ms (each channel is preset by default)
works with CAPAROC PM IOLs and CAPAROC PM PN power modules
required spare fuse only in I of the power supplymax> Short circuit switching capacity when required. Built-in fail-safe element.
Short-circuit switch capacity 300 A
dielectric strength 35V DC (load circuit)
Active Current Limit Typical value at IN≤ 3 AN
IN= 4 A, typically 1.5 x IN
Fuse electronic
efficiency > 99%
closed-circuit current I0 Typical 25 mA (no load at 24V)
power consumption Typical 0.6W (no load at 24V)
< 1.1W (normal operation at 24V,4 A)
Measurement Tolerance I ± 10 % (2 A ... 4 A)
± 20 % (1 A)
MTBF (IEC 61709, SN 29500) 11364927 h (25°C, 21% load)
5271554 h (40°C at 34.25% load)
640731 h (at 100% load at 65°C)
voltage drop 0.06V (at 4 A)
fail-safe components 5 A DC (per output channel)
Contact Type without electrical isolation
Load Circuit
Downtime 5 s (IN≥ 4 A… 1.3 x IN)
5 s (in IN< 4 A… 1.7 x IN)
≤ 400 ms (maximum 450 ms for large starting current)
Typical 20 ms (for short circuit> 1.5 x IN)
undervoltage shutdown ≤ 8.5V DC (active)
≥ 9.2V DC (passive)
Overvoltage shutdown ≥ 32.5V DC (active)
≤ 30.5V DC (passive)
Maximum capacitive load ≤ 60000 & micro;F (depending on current setting and available short-circuit current)

fuse protection output
Connection Mode in-line connection
stripping length 10mm
Flexible Wire Cross Section 0.2 mm² ... 4 mm²
Rigid conductor cross section 0.2 mm² ... 4 mm²
Attachable Guide Cross Section AWG 24 ... 12