Phoenix CN-UB-70DC-6-SB-surge protector 2803153, surge protection adapter with coaxial signal interface surge protection device. Connection: N connector, pin/hole type

Product Type Transceiver System
IEC Category C2
C3
D1
VDE requirement level C2
C3
D1
type Protection Adapter
Surge protection fault alarm None

Connection Mode Type-N connector, 50 Ω
Tightening torque 1.4 Nm ... 1.7 Nm (N coupling nut)

Dimensional drawing
width 24mm
height 24mm
depth 50mm

color NICKEL
sealing material silicon
Shell Material brass (copper zinc alloy)
Shell surface material Ni
Core Material BeCu
Core Surface Material gold
Insulator Material PTFE

Mechanical parameters
Open Side Panel No

Direction of action Line-Shield/Earth Ground
Maximum continuous operating voltage UC 70V DC
50V AC
Maximum continuous operating voltage UC(core-ground) 70V DC
50V AC
Rated current 10 A
UC, the effective working current IC ≤ 1 µA
Nominal discharge current In(8/20) µs 5 kA
Rated discharge current In(8/20)& micro;s (core-ground) 5 kA
Nominal discharge current In(8/20)& micro;s (core/shield) 5 kA
pulse discharge current Iimp(10/350) µs 1 kA
pulse discharge current Iimp(350) & micro;s (core-ground) 1 kA
Maximum discharge current Imax(8/20) & micro;s (core-ground) 10 kA
Maximum discharge current Imax(8/20) & micro;s (core-shield) 10 kA
rated power pulse current lan (1000)& micro;s (core-shield) 100 A
impulse current (10/350) & micro;s (L-N), peak current Iimp 1 kA
Output voltage limit 1 kV/& micro;s (core-ground) peak ≤ 650V
Output voltage limit 1 kV/& micro;s (core-shield) peak ≤ 650V
Output voltage limit 1 kV/& micro;s (core-ground) static ≤ 650V
output voltage limit 1 kV/& micro;s (core-shield) static ≤ 650V
voltage protection level Up(line-ground) ≤ 800V (C2 - 4 kV / 2 kA)
≤ 1 kV (C2 - 10 kV / 5 kA)
voltage protection level Up(core-shield) ≤ 800V (C2 - 4 kV / 2 kA)
≤ 1 kV (C2 - 10 kV / 5 kA)
response time tA (core-ground) ≤ 100 ns
response time tA (core-shield) ≤ 100 ns
input attenuation AE, asymmetric. 0.1 dB (≤ 6 GHz)
cutoff frequency fg(3 dB), asymmetric. (shielded) in a 50 Ω system > 6 GHz
Frequency Range 0Hz ... 6 GHz
50 Ω system Typical 1.15 (≤ 6 GHz)
Allowable high-frequency power Pmax,VSWR = xx(50 ohm system) 30W (VSWR=1.15)
capacitance (core-ground) Typical 1.5 pF
Capacitance Asymmetry (Shielded) Typical 1.5 pF
Surge protection fault alarm None
Impact resistance (line-ground) C2 - 10 kV / 5 kA
C3 - 100 A
D1 - 1 kA
Impact resistance (line-shield) C2 - 10 kV/5 kA
C3 - 100 A
D1 - 1 kA
alternating current carrying capacity (wire-shield) 5 A - 1 s

environmental conditions
protection level IP68
IP68
ambient temperature (operation) -40°C ... 90°C
2803166

Phoenix CN-UB-70DC-6-SB-Surge Protector 2803153

Product Center