Phoenix FLT-SEC-H-T1-1C-264/25-FM-1 Class 2 combined surge protector 2801615, plug-in lightning protection protector, meet the requirements of Class 1/Class I, built-in anti-surge fuse, used for single-phase power network, Zero-to-ground (L1, PEN).
Product Type
combination type
Product Series
SEC Family
IEC Category
I / II
EN Type
T1 / T2
IEC power supply system
TN-C
TT
type
DIN rail module, split, detachable
Bits
1
Surge protection fault alarm
visual status indication window and remote alarm contact
insulation characteristics
Overvoltage Category
III
pollution level
2
Rated frequency fN
50Hz (60 Hz)
indicator/remote signaling
Connection Name
Remote alarm contact
switching function
changeover contact
Nominal operating voltage
12V AC ... 250V AC
125V DC (200 mA DC)
Operating current
10 mA AC ... 1 A AC
1 A DC (30V DC)
Connection Mode
screw connection
thread
M5
Tightening torque
4.5 Nm
stripping length
18mm
Flexible Wire Cross Section
2.5 mm² ... 35 mm²
Rigid conductor cross section
2.5 mm² ... 35 mm²
Attachable Guide Cross Section AWG
13 ... 2
Connection Mode
fork cable end
Flexible Wire Cross Section
1.5 mm² ... 16 mm²
Remote alarm contact
Connection Mode
COMBICON in-line/screw connection
thread
M2
Tightening torque
0.25 Nm
stripping length
7mm
Flexible Wire Cross Section
0.14 mm² ... 1.5 mm²
Rigid conductor cross section
0.14 mm² ... 1.5 mm²
Attachable Guide Cross Section AWG
28 ... 16
Dimensional drawing
width
35.5mm
height
167mm
depth
74.5mm (7.5mm with DIN rail)
Horizontal stitch pitch
Division 2
color (pin connector)
light gray (RAL 7035)
color (basic element)
gray (RAL 7042)
flame retardant rating to UL 94
V-0
material
600
insulation material
PA 6.6-FR 20% GF
PBT-FR
Material Group
I
Shell Material
PA 6.6-FR 20 % GF
PBT-FR
Mechanical parameters
Open Side Panel
No
protection channel
L-PEN
movement direction
1L-N/PE
Rated voltage UN
240V AC (TN-C)
Rated frequency fN
50Hz (60 Hz)
Maximum continuous operating voltage UC
264V AC
Nominal discharge current In(8/20)µs
25 kA
Maximum discharge current Imax(8/20) µs
50 kA
impulse discharge current (10/350)& micro;s, charging
12.5
impulse discharge current (10/350)& micro;s, specific energy
160 kJ/Ω
impulse discharge current (10/350)& micro;s, peak limp
25 kA
Disconnect freewheeling capacity Ifi
50 kA
Rated short-circuit current ISCCR
50 kA
voltage protection level Up
≤ 1.5 kV
Residual pressure Ures
≤ 1.5 kV (In)
≤ 2.5 kV (at 50 kA)
≤ 1.2 kV (at 12.5 kA)
≤ 1 kV (at 5 kA)
≤ 0.9 kV (at 2.5 kA)
6 kV (1.2/50) & micro;s
≤ 1.5 kV
UT
415V AC (5 seconds/withstand mode)
460V AC (120 min/tolerance mode)
response time tA
≤ 100 ns
2801615
넳넲
Phoenix FLT-SEC-H-T1-1C-264/25-FM - 1 Class 2 Combined Surge Protector 2801615