Phoenix CT 10-18FS F/PE-24-Surge Protector-Plug-in 2807926,LSA-PLUS surge protection plug (COMTRAB CT 10), used for thick/thin surge between 18 signal lines and GND Protection and GND-PE coarse protection. Rated voltage: 24V DC. Model: 10 double lines.

Product Type measurement and control technology
Product Series COMTRAB
IEC Category C1
C2
C3
D1
type LSA-PLUS module
Surge protection fault alarm None
can test protectors using the CHECKMASTER software tests:
insulation characteristics
Overvoltage Category III
pollution level 2

Rated voltage UN 24V DC
24V AC

Connection Mode can be inserted into COMTRAB-TERMIBLOCK and break/switch terminal strip LSA-PLUS

Dimensional drawing
width 111mm
height 22mm
depth 68.5mm

color black (RAL 9005)
flame retardant rating to UL 94 V-0
Shell Material PBT

Mechanical parameters
Open Side Panel No

movement direction Line-Signal Ground/Shield & Signal Ground/Shield-Earth Ground
Maximum continuous operating voltage UC 40V DC
28V AC
Rated current 1.5 A AC (75 °C)
350 mA DC (75 °C)
UC, the effective working current IC ≤ 5 µA (18x)
Residual Flow IPE ≤ 1 µA (19x)
Nominal discharge current In(8/20) & micro;s (core-core) 119 A (per path)
Rated discharge current In(8/20)& micro;s (core-ground) 5 kA (per path)
Nominal discharge current In(8/20)& micro;s (signal ground-ground) 5 kA (per path)
pulse discharge current Iimp(350) & micro;s (core-ground) 2.5 kA
pulse discharge current Iimp(10/350) & micro;s (signal ground-ground) 2.5 kA
Total discharge current ITotal(8/20) µs 10 kA
Maximum discharge current Imax(8/20) & micro;s (core-core) 119 A (per path)
Maximum discharge current Imax(8/20) & micro;s (core-ground) 5 kA (per path)
Nominal pulse current Ian (10/1000) & micro;s (line-signal ground) 23 A
Output voltage limit 1 kV/& micro;s (core-ground) peak ≤ 650V
Output voltage limit at 1 kV /μs (line-signal ground) spikes ≤ 70V
output voltage limited to 1 kV/& micro;s (line-signal ground) static ≤ 60V
Residual voltage ln,(wire-ground) ≤ 30V
In(line-signal ground) ≤ 85V
Ian (1000)& micro; Residual voltage at s (line-signal ground) ≤ 65V
response time tA (core-ground) ≤ 100 ns
response time tA (line-signal ground) ≤ 1 ns
input attenuation AE, asymmetric. Typical 0.1 dB (≤ 2 MHz / 50 Ω)
Typical 0.1 dB (≤ 200 kHz / 150 Ω)
Typical 0.1 dB (≤ 80 kHz/600 Ω)
cutoff frequency fg(3 dB), asymmetric. 50 Ω system (signal ground) Typical 10 MHz
cutoff frequency fg(3 dB), asymmetric. 150 Ω in the system (signal ground) Typical 2.5 MHz
cutoff frequency fg(3 dB), asymmetric. 600 Ω in the system (signal ground) Typical 650 kHz
capacity (line-signal ground) Typical 1.1 nF (1 MHz)
Surge protection fault alarm None
Impact resistance (line-ground) C2 - 10 kV / 5 kA
D1 - 2.5 kA
Surge current carrying capacity (line-signal ground) C3 - 23 A
Impact resistance (signal ground-ground) D1 - 2.5 kA
2807926