Phoenix MINI MCR-2-UI-UI-isolation amplifier 2902037,3-terminal isolation amplifier, using plug-in connection technology, with calibration measurement range switching function, can be used for electrical isolation of unipolar and bipolar analog signals. The input/output can be configured via a DIP switch. Screw connection technology, standard configuration.

Product Type isolation amplifier
Product Series MINI Analog Pro
Channels 1
Model isolation amplifier
configuration DIP switch
insulation characteristics: GB Standard
Overvoltage Category II
pollution level 2

electrical isolation 3 End Isolation
galvanic isolation between input and output is
cut-off frequency (3dB) 30Hz (via DIP switch)
5 kHz (via DIP switch)
protection circuit transient protection
step response (10-90%) < 12 ms (with 30Hz filter)
maximum temperature coefficient 0.01 %/K
temperature coefficient, typical 0.01 %/K
Maximum transmission error ≤ 0.1 % (maximum value of configured output range)
≤ 0.15 % (final value, IN:4 mA ... 20 mA / OUT:-10V ... 10V)
Electrical isolation input/output/power supply
Rated insulation voltage 300Vrms
Test Voltage 3 kV AC (50 Hz, 60 s)
insulation reinforced insulation conforming to IEC/EN 61010-1
power supply
Rated supply voltage 24V DC
Supply Voltage Range 9.6V DC ... 30V DC (DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, order number 2869728) can be used to bridge the power supply. Can be stuck to a 35mm DIN rail conforming to the EN60715 standard))
Typical current consumption 25 mA (24V DC current output with load)
54 mA (current output, 12V DC including load)
power consumption (I output) ≤ 800 mW (IOUT= 20 mA,9.6V DC,600 Ω load)

signal: current/voltage
Input Number 1
configurable/programmable is
voltage input signal 0V ... 5V (via DIP switch)
1V ... 5V (via DIP switch)
-5V ... 5V (via DIP switch)
0V ... 10V (via DIP switch)
2V ... 10V (via DIP switch)
-10V ... 10V (via DIP switch)
0V ... 20V (via DIP switch)
4V ... 20V (via DIP switch)
-20V ... 20V (via DIP switch)
0V ... 24V (via DIP switch)
4.8V ... 24V (via DIP switch)
-24V ... 24V (via DIP switch)
0V ... 30V (via DIP switch)
6V ... 30V (via DIP switch)
-30V ... 30V (via DIP switch)
Maximum voltage input signal 33V
current input signal 0 mA ... 20 mA (via DIP switch)
4 mA ... 20 mA (via DIP switch)
-20 mA ... 20 mA (via DIP switch)
Maximum current input signal 24 mA
input voltage > 1000 kΩ
input current approx. 63 Ω (+0.7V for testing diodes)
2902040

Phoenix MINI MCR-2-UI-UI-Isolation Amplifier 2902037

Product Center