Phoenix MINI MCR-BL-UI-UI-isolation amplifier 1070346,3-terminal signal isolation transmitter, used for galvanic isolation of analog signals, I/O can be configured by DIP switch, screw connection, standard configuration
Product Type
isolation amplifier
Product Series
MINI Analog
Channels
1
Model
Input Isolation Amplifier
insulation characteristics
Overvoltage Category
II
pollution level
2
electrical isolation
3 End Isolation
galvanic isolation between input and output
is
cut-off frequency (3dB)
approx. 100Hz
step response (10-90%)
3.2 ms
temperature coefficient, typical
< 0.002 %/K
Maximum transmission error
< 0.2 % (of terminal value)
< 0.5 % (without mediation)
Electrical isolation input/output/power supply
Rated insulation voltage
50V AC/DC
Test Voltage
1.5 kV AC (50 Hz, 60 s)
insulation
foundation isolation conforming to IEC/EN 61010
Power
Rated supply voltage
24V DC
Supply Voltage Range
19.2V DC ... 30V DC (DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, order number 2869728) can be used to bridge the power supply. Can be stuck to a 35mm DIN rail conforming to the EN60715 standard))
Maximum current consumption
< 19 mA (current output under load at 24V DC)
< 9 mA (voltage output under load at 24V DC)
power consumption (I output)
< 450 mW (current output)
power consumption (U output)
< 200 mW (voltage output)
signal: current/voltage
Input Number
1
configurable/programmable
Yes, pre-configured
voltage input signal
0V ... 10V
0V ... 5V
1V ... 5V
2V ... 10V
Maximum voltage input signal
30V
current input signal
0 mA ... 20 mA
4 mA ... 20 mA
Maximum current input signal
50 mA
input voltage
about 100 kΩ
input current
approx. 50 Ω
signal: current/voltage
voltage output signal
0V ... 10V
0V ... 5V
1V ... 5V
2V ... 10V
Maximum voltage output signal
about 12.5V
No-load voltage
about 12.5V
current output signal
0 mA ... 20 mA
4 mA ... 20 mA
Maximum current output signal
28 mA
2810492
넳넲
Phoenix MINI MCR-BL-UI-UI-Isolation Amplifier 1070346