Phoenix PSR-MC32-3NO-1NC-24-230UC-SC-safety relay 2700524, safety relay, used for emergency stop, safety door and grating, safety level up to SIL 3, Cat. 4, PL e, single channel or dual channel operation, automatic or manual, controlled start, 3 enable current paths, 1 signal current path, US = 24 ... 230V AC/DC, plug-in screw terminal
| Product Type | safety relay |
| product series | PSRmini |
| Application | Emergency stop button |
| safety door | |
| electromagnetic switch | |
| answering machine | |
| grating | |
| control | Single and Dual Channel |
| Relay Model | Electromechanical relay with mechanical interlocking contacts according to IEC/EN 61810-3 |
| insulation characteristics | |
| Overvoltage Level | III |
| pollution level | 2 |
| Typical Response Time | < 150 ms (auto start) |
| < 100 ms (manual, monitoring start) | |
| Typical startup time (Us) | < 200 ms (when controlled via A1) |
| response time | < 200 ms (when requested via A1; application deactivation via A1/A2 not allowed) |
| Typical release time | < 20 ms (via sensor loop as required) |
| restart time | < 1 s (start-up time) |
| Recovery Time | < 500 ms (meets the requirements of safety functions) |
| 100 ms (available time after sensor circuit is activated during manual start) | |
| Start Pulse Length | 500 ms minimum (manual reset) |
| rated conditions | 17.3W (in IL² = 72 A²) |
| Rated operating mode | 100% Eligible |
| Rated insulation voltage | 250V AC |
| rated overvoltage/insulation | See chapter "Insulation Coordination" |
| power supply | |
| Name | A1/A2 |
| Rated control circuit supply voltage US | 24V AC/DC ... 230V AC/DC -15 % / +10% |
| Rated control supply current IS | Typical 103 mA (24V DC) |
| Typical 47 mA (48V DC) | |
| Typical 38 mA (110V AC) | |
| Typical 21 mA (230V AC) | |
| US | 2.7W (DC applicable) |
| 2.9W (AC) | |
| apparent power | typical 5 VA (US) |
| Impulse current | < 80 A (Us, & Delta;t = 50 & micro;s) |
| filter time | 2 ms (at A1, at the voltage dip Us) |
| protection circuit | 275V Varistor/411V Suppressor Diode |
| digital quantity: sensor circuit (S10,S12,S13,S22) | |
| Input Description | safety-related sensor inputs |
| IEC 61131-2 Type 3(S10, S12, S13) Current, input (S10, S12, S13) Current, output (S22) |
|
| Input Quantity | 4 |
| input voltage range, "0" signal | 0V DC ... 5V DC (for safety shutdown; at S10/S12/S13) |
| input voltage range, "1" signal | 11V DC ... 30V DC (S10/S12/S13) |
| Input current range "0" signal | 0 mA ... 2 mA (for safety shutdown; at S10/S12/S13) |
| Impulse current | < 5 mA (S10/S12/S13, usually US) |
| > -5 mA (S22 input, voltage is usually US) | |