Phoenix PSI-MOS-PROFIB/FO 850 E-FO converter 2708274, fiber optic converter, built-in optical diagnosis function, alarm contact, for PROFIBUS up to 12 Mbps, with a fiber optic interface (BFOC) on the terminal equipment, 850 nm, Suitable for PCF/fiber optic cable (multimode)
Product Type
Media Converter
Product Series
PSI-MOS
MTTF
247 years (SN 29500 standard, temperature 25°C, duty cycle 21%)
200 years (SN 29500 standard, temperature 40°C, duty cycle 34.25%)
130 years (SN 29500 standard, temperature 40°C, duty cycle 100%)
MTBF
252 years (Telcordia standard, temperature 25°C,21% operation cycle (5 days a week, 8 hours a day))
42 years (Telcordia standard, temperature 40°C,34.25% operation cycle (5 days a week, 12 hours a day))
electrical isolation
VCC // RS-485
rated conditions
2.88W
test voltage data interface/power supply
1.5 kVrms(50 Hz,1 min)
Power
Supply Voltage Range
18V DC ... 30V DC (via plug-in COMBICON screw terminal block)
Rated supply voltage
24V DC (UL compliant)
Typical current consumption
120 mA (24V DC)
Maximum current consumption
130 mA
≤ 2 A (via DIN rail connector when running in connection site)
switching
Output Name
relay output
Output Description
Alarm output
outputs
1
maximum switching voltage
60V DC (resistive load, universal load)
30V AC (resistive load)
42V AC (peak, resistive load)
limit continuous current
0.46 A
Power
Connection Mode
plug-in COMBICON screw terminal block
stripping length
7.00mm
Tightening torque
0.56 Nm ... 0.79 Nm
-bit distortion, input
± 35% (allowed)
-bit distortion output
< 6.25%
bit delay
< 1 Bit (DIP 7 = OFF, standard run)
11 Bit (DIP 7 = ON, redundant operation)
signal
PROFIBUS
data: optical fiber
Channels
1
minimum transmission power
-4.2 dBm (200/230 µm)
-17.8 dBm (50/125 µm)
-14.6 dBm (62.5/125µm)
transmission length, including 3 dB system margin
2600 m (F-G 50/125 2.5dB/km)
3300 m (F-G 62.5/125 3.0dB/km)
800 m (F-K 200/230 10 dB/km with quick-mount connector)
Transfer Protocol
RS-485 interface, protocol transparency
Connection Mode
B- FOC (ST®)
wavelength
850 nm
Minimum Receiving Sensitivity
-30 dBm (50/125 µm)
receiver
-3 dBm (200/230 µm)
transmission medium
PCF fiber
multimode glass fiber
Data: PROFIBUS according to IEC 61158, RS-485 2-wire, half-duplex, automatic control
serial transmission rate
≤ 12 Mbps
Connection Mode
D-SUB-9 female connector
Transmission Length
≤ 1200 m (depending on rate, shielded twisted pair)