Phoenix PSI-MOS-RS422/FO 850 T-FO converter 2708397, fiber optic converter, built-in optical diagnosis function, alarm contact, for RS-422/RS-485 4-wire system/INTERBUS up to 2 Mbps, T-coupler with two fiber optic interfaces (BFOC),850 nm, suitable for PCF/fiber optic cable (multimode)

Product Type Media Converter
Product Series PSI-MOS
MTTF 746 years (SN 29500 standard, temperature 25°C, duty cycle 21%)
309 years (SN 29500 standard, temperature 40°C, duty cycle 34.25%)
128 years (SN 29500 standard, temperature 40°C, duty cycle 100%)
MTBF 178 years (Telcordia standard, temperature 25°C,21% operation cycle (5 days a week, 8 hours a day))
26 years (Telcordia standard, temperature 40°C,34.25% operation cycle (5 days a week, 12 hours a day))

electrical isolation VCC // RS-422
rated conditions 2.88W
test voltage data interface/power supply 1.5 kVrms(50 Hz,1 min)
power supply
Supply Voltage Range 18V DC ... 30V DC
Rated supply voltage 24V DC (UL compliant)
Typical current consumption 120 mA (24V DC)
Maximum current consumption 130 mA
≤ 2 A (via DIN rail connector when running in connection site)

switching
Output Name relay output
Output Description Alarm output
outputs 1
maximum switching voltage 60V DC
42V AC
limit continuous current 0.46 A

power supply
Connection Mode plug-in COMBICON screw terminal block
Tightening torque 0.56 Nm ... 0.79 Nm

-bit distortion, input ± 35% (allowed)
-bit distortion output < 6.25%
signal INTERBUS
transmission channel 2(1/1)RD, TD, Full Duplex
data: optical fiber
Channels 2
minimum transmission power -4.6 dBm (200/230 &micro;m)
-17.6 dBm (50/125 &micro;m)
-13.6 dBm (62.5/125&micro;m)
transmission length including 3 dB system margin 2800 m (F-K 200/230 10 dB/km with quick-mount connector)
4200 m (F-G 50/125 2.5dB/km)
4800 m (F-G 62.5/125 3.0dB/km)
Transfer Protocol is transparent to RS-422 interface protocols
Connection Mode B- FOC (ST®)
wavelength 850 nm
Minimum Receiving Sensitivity -33.2 dBm
transmission medium PCF fiber
multimode glass fiber
data: RS-422 interface according to ITU-T V.11,EIA/TIA-422,DIN 66348-1
serial transmission rate ≤ 2 Mbps
Connection Mode pluggable screw connection
Transmission Length ≤ 1000 m (depending on data rate, shielded stranded data cable)
terminal resistance 220 Ω
100 Ω
220 Ω
single wire/wiring point, rigid 0.2 mm² ... 2.5 mm²
single wire/wiring point, flexible 0.2 mm² ... 2.5 mm²
AWG Strand Maximum Cross Section, Flexible 14
AWG Wire Minimum Cross Section, Flexible 24
single wire/wiring point, maximum rigid AWG 14
Single Wire/End Point, Minimum Rigid AWG 24
transmission medium copper cable
File Format/Encoding UART(11Bit,NRZ)

width 35mm
height 99mm
depth 103mm
2708342

Phoenix PSI-MOS-RS422/FO 850 T-FO Converter 2708397

Product Center

PRODUCT CENTER