Phoenix ELR H3-IES-PT-24DC/500AC-06-T-Hybrid Motor Starter 2906061, Hybrid Motor Starter; Function: start motor, motor protection (grade 10A), emergency stop button, higher transient voltage tolerance, ATEX; Input: 24V DC; Output: 3 ~, 500V AC, 600 mA; In-line connection
| Product Type |
hybrid motor starter |
| product series |
CONTACTRON |
| Mode of operation |
100% operating factor |
| phase number |
3 |
| Motor Starter Type |
direct starter |
| Switching frequency |
≤ 2Hz (depending on load) |
| rated conditions |
0.4W |
| Switching frequency |
≤ 2Hz (depending on load) |
| maximum power loss |
1.5W |
| minimum power loss |
1.1W |
| type of coordination |
1 |
| power supply |
| Rated control circuit supply voltage US |
24V DC |
| Control Supply Voltage Range |
19.2V DC ... 30V DC |
| Rated control supply current IS |
40 mA |
| protection circuit |
surge protection |
| polarity protection |
| insulation characteristics |
| Rated insulation voltage |
500V |
| Rated overvoltage |
6 kV |
| Overvoltage Level |
III |
| pollution level |
2 |
| control input and control supply voltage and insulation characteristics from auxiliary circuit to main circuit |
safety insulation (IEC 60947-1/EN 50178) for operating voltages ≤ 300V AC |
| operating voltage 300V AC ... 500V AC (IEC 60947-1) |
| safety insulation (EN 50178), suitable for working voltage 300 ... 500V AC |
| control input and control supply voltage to auxiliary circuits |
safety insulation (IEC 60947-1),≤ 300V AC in auxiliary circuits |
| safety insulation (EN 50178), in auxiliary circuits ≤ 300V AC |
| control |
| Enter Name |
Control Input |
| Rated operating voltage UC |
24V DC |
| Trigger voltage range |
19.2V DC ... 30V DC |
| Rated operating current IC |
5 mA |
| Switch Threshold |
9.6V ("0" signal) |
| 19.2V ("1" signal) |
| switch level |
< 5V DC (for emergency stop) |
| Typical closing time |
< 30 ms |
| protection circuit |
polarity protection |
| AC output |
| Considerations |
1200V Semiconductor |
| Rated operating voltage Ue |
500V AC |
| Operating voltage range |
42V AC ... 550V AC |
| Rated operating current Ie |
0.6 A (AC-51) |
| 0.6 A (AC-53a) |
| mains frequency |
50/60Hz |
| Load current range |
75 mA ... 600 mA (see attenuation curve) |
| action characteristics according to IEC 60947-4-2 |
Class 10A |
| cooling time |
20 min |
| leakage current |
0 mA |
| protection circuit |
surge protection |
| Confirm Output |
| Considerations |
confirmation: floating transfer contact, signal contact |
| Contact Type |
1 changeover contact |
| switching capacity according to IEC 60947-5-1 |
3 A (230 V, AC15) |
| 2 A (24V (DC13)) |
| control loop |
| Connection Mode |
in-line connection |
| stripping length |
10mm |
| Rigid conductor cross section |
0.2 mm² ... 2.5 mm² |
| Flexible Wire Cross Section |
0.2 mm² ... 2.5 mm² |
| Attachable Guide Cross Section AWG |
24 ... 14 |
| Load Circuit |
| Connection Mode |
in-line connection |
| stripping length |
10mm |
| Rigid conductor cross section |
0.2 mm² ... 2.5 mm² |
| Flexible Wire Cross Section |
0.2 mm² ... 2.5 mm² |
| Attachable Guide Cross Section AWG |
24 ... 14 |
| Status Display |
LED (yellow) |
| Operating voltage display |
Green LED |
| error indication |
Red LED |
| width |
22.5mm |
| height |
107.5mm |
| depth |
114mm |