Phoenix ELR H51-IES-24DC500AC-3-IFS-hybrid motor starter 1151618, hybrid motor starter, functions: motor start, commutation, protection and emergency stop, networking, short circuit protection, input: 24V DC; Output: 3~500V AC,3 A; Connection method: screw and in-line connection, can be connected to the interface system

Product Type hybrid motor starter
Product Series CONTACTRON
Mode of operation 100% operating factor
insulation characteristics: standards/regulations
pollution level 2

phase number 3
Motor Starter Type reversible starter
Switching frequency ≤ 2Hz (depending on load)
rated conditions 2.5W
Switching frequency ≤ 2Hz (depending on load)
Maximum power loss 4.1W
minimum power loss 0.88W
type of coordination 1
power supply
Rated control circuit supply voltage US 24V DC
Control Supply Voltage Range 19.2V DC ... 30V DC
Rated control supply current IS 60 mA
protection circuit surge protection
polarity protection; parallel polarity protection diode
insulation characteristics
Rated insulation voltage 550V
Rated overvoltage 6 kV
Overvoltage Level III
pollution level 2
insulation characteristics between the control input voltage and the control supply voltage of the main circuit safety insulation (IEC 60947-1)
emergency trip
Operating Threshold > 33 A
response time < 0.5 s

control
Enter Name Enable Input
Considerations The enable input is compatible with the blanking signal (semiconductor output signal, test pulse duration not exceeding 3 ms),
A turn-on pulse of up to 4 ms is permitted without adversely affecting the safety function.
Rated operating voltage UC 24V DC
Trigger voltage range 19.2V DC ... 30V DC
Rated operating current IC 7 mA
Switch Threshold 9.6V ("0" signal)
19.2V ("1" signal)
switch level < 5V DC (for emergency stop)
Typical closing time < 30 ms
protection circuit polarity protection

AC output
Rated operating voltage Ue 500V AC
Operating voltage range 42V AC ... 550V AC
Rated operating current Ie 3 A (AC-51)
3 A (AC-53a)
mains frequency 50/60Hz
Load current range 180 mA ... 3 A (see attenuation curve)
action characteristics according to IEC 60947-4-2 Class 10
cooling time 20 min (for automatic reset)
leakage current 0 mA
protection circuit Surge protection; Varistor

control loop
Connection Mode in-line connection
stripping length 10mm
Rigid conductor cross section 0.2 mm² ... 2.5 mm²
Flexible Wire Cross Section 0.2 mm² ... 2.5 mm²
Attachable Guide Cross Section AWG 24 ... 14
Load Circuit
Connection Mode screw connection
stripping length 8mm
thread M3
Rigid conductor cross section 0.2 mm² ... 2.5 mm²
Flexible Wire Cross Section 0.2 mm² ... 2.5 mm²
Attachable Guide Cross Section AWG 24 ... 14
Tightening torque 0.5 Nm ... 0.6 Nm
5 lbf-in. ... 7 lbf-in.

Status Display LED (yellow)
Operating voltage display Green LED
error indication Red LED
2902744

Phoenix ELR H51-IES-24DC500AC-3-IFS-Hybrid Motor Starter 1151618

Product Center