Phoenix ELR H51-IESSC-24DC500AC-06-hybrid motor starter 2902746, short-circuit protected hybrid motor starter, used for reverse starting three-phase AC motors, up to 550V AC,24V DC input, 0.6 A output current, emergency stop function and Adjustable overload break. Use only in combination with EM-RD and EM-RI adapters or power distribution boards.

Product Type hybrid motor starter
product series CONTACTRON
Mode of operation 100% operating factor

phase number 3
Motor Starter Type reversible starter
Switching frequency ≤ 2Hz (depending on load)
rated conditions 1.7W
Switching frequency ≤ 2Hz (depending on load)
Maximum power loss 2.8W
minimum power loss 0.88W
type of coordination 2
power supply
Rated control circuit supply voltage US 24V DC
Control Supply Voltage Range 19.2V DC ... 30V DC
Rated control supply current IS 40 mA
protection circuit surge protection
polarity protection; parallel polarity protection diode
insulation characteristics
Rated insulation voltage 500V
Rated overvoltage 6 kV
Overvoltage Level III
pollution level 2
control input and control supply voltage and insulation characteristics from auxiliary circuit to main circuit safety insulation (IEC 60947-1) for operating voltages ≤ 300V AC
operating voltage 300V AC ... 500V AC (IEC 60947-1)
control input and control supply voltage to auxiliary circuits safety insulation (IEC 60947-1),≤ 300V AC in auxiliary circuits

control
Enter Name Control Input Right/Left
Rated operating voltage UC 24V DC
Trigger voltage range 19.2V DC ... 30V DC
Rated operating current IC 5 mA
Switch Threshold 9.6V ("0" signal)
19.2V ("1" signal)
switch level < 5V DC (for emergency stop)
Typical closing time < 30 ms
protection circuit polarity protection

AC output
Rated operating voltage Ue 500V AC
Operating voltage range 42V AC ... 550V AC
mains frequency 50/60Hz
Load current range 75 mA ... 600 mA (see attenuation curve)
action characteristics according to IEC 60947-4-2 Class 10A
cooling time 20 min (for automatic reset)
leakage current 0 mA
protection circuit Surge protection; Varistor
short-circuit protection; fuse
Confirm Output
Considerations confirmation: floating transfer contact, signal contact
Contact Type 1 changeover contact
switching capacity according to IEC 60947-5-1 3 A (230 V, AC15)
2 A (24V (DC13))

control loop
Connection Mode screw connection
stripping length 8mm
thread M3
Rigid conductor cross section 0.2 mm² ... 2.5 mm²
Flexible Wire Cross Section 0.2 mm² ... 2.5 mm²
Connectable Guide Cross Section AWG 24 ... 14
Tightening torque 0.5 Nm ... 0.6 Nm
5 lbf-in. ... 7 lbf-in.
2902744

Phoenix ELR H51-IESSC-24DC500AC-06-Hybrid Motor Starter 2902746