Phoenix ESSENTIAL-PS/3AC/24DC/960W/EE-power 1018294,ESSENTIAL edition power supply, primary switch mode, for DIN rail installation, input: 3 phase, output: 24V DC/960W
| AC operation | |
| Rated input voltage range | 3x 400V AC ... 500V AC |
| Input Voltage Range | 3x 320V AC ... 575V AC |
| AC input voltage range | 3x 320V AC ... 575V AC |
| Supply Voltage | AC |
| Impulse current | < 20 A |
| impulse current integral (I2t) | 1.3 A2s |
| AC frequency range | 45Hz ... 65Hz |
| grid buffer time | > 16 ms (3x 400V AC) |
| power consumption | 3x 2 A (400V AC) |
| 3x 1.6 A (480V AC) | |
| Rated power consumption | 1149.27 VA |
| protection circuit | transient surge protection; varistor |
| Typical Response Time | < 1 s |
| recommend use | 10 A ... 16 A (UL: 20 A) |
| PE discharge current | < 3.5 mA |
| efficiency | 91.5 % (at 400V AC and rated) |
| output characteristics | U/ I |
| Rated output voltage | 24V DC ±1% |
| output voltage (USet) setting range | 22.5V DC ... 29.5V DC (> 24V DC, stable capacity limit) |
| Rated output current (IN) | 40 A (UOUT= 24V DC) |
| Attenuation | 55°C ... 70°C (2.5 %/K) |
| feedback voltage resistance | 35V DC |
| output | < 35V DC |
| Active Current Limit | about 42 A |
| residual wave | < 20 mVSS |
| Short-circuit protection | is |
| output power | 960W |
| peak switching voltage rated load | < 40 mVSS |
| maximum no-load power consumption | 11W |
| Maximum rated load power loss | 87W |
| and connect | Yes, for redundancy and increased capacity |
| Input | |
| Connection Mode | screw connection |
| Minimum cross section of rigid conductor | 0.2 mm² |
| Maximum cross section of rigid conductor | 6 mm² |
| Minimum cross section of flexible lead | 0.2 mm² |
| flexible conductor | 4 mm² |
| Minimum Wire Cross Section AWG | 22 |
| Maximum conductor cross section AWG | 10 |
| stripping length | 8mm |
| Minimum tightening torque | 0.5 Nm |
| Maximum tightening torque | 0.6 Nm |
| Output | |
| Connection Mode | screw connection |
| Minimum cross section of rigid conductor | 0.5 mm² |
| Maximum cross section of rigid conductor | 16 mm² |
| Minimum cross section of flexible lead | 0.5 mm² |
| flexible conductor | 10 mm² |
| Minimum Wire Cross Section AWG | 8 |
| Maximum conductor cross section AWG | 6 |
| stripping length | 10mm |
| Minimum tightening torque | 1.2 Nm |
| Maximum tightening torque | 1.5 Nm |
| Signal Type | LED |
| Operating voltage display | Green LED |
| signal output | |
| Status Display | DC OK LED green |
| Notes on Status Display | UOutput>21.5V: LED on |
| phase number | 3 |
| insulation voltage input/output | 3 kV AC (type test) |
| 1.5 kV AC (regular test) | |
| insulation voltage output/PE | 500V DC |